Covesa Soluciones Industriales

XS16SI

Tabla de contenidos

Especificaciones

Device Type

Safety Controller

In-Series Diagnostics

No

Safety Module Type

Input Module

LCD Display

No

Expandable

Yes

Dimension (H x W x D in mm)

110 x 22.5 x 129

Relative Humidity

90% @ 50° C

Max Operating Temperature ( °C)

55

Input Operation

Simultaneous or Concurrent

Number of Safe Inputs

16

Input Configuration

Configurable

Number of Convertible Inputs

4

Safety Input – Dual Channel (Dry Contact)

5-50 mA @ 24 V dc

Safety Input – Dual Channel (Solid-State)

50 mA @ 15 – 30 V dc

Safety Input – Reset

5-50 mA @ 24 V dc

Non Safe Output Configuration

Up to 4 PNP

Non Safe Output Rating

80 mA @ 24 V dc (individual) maximum; overcurrent protected

Safe Output Rating

N/A

Splittable Safe Output

No

Power Consumption

0.09 A (no load); 0.41 A (full load)

Response Time (ms)

See Software Configuration Summary

Terminal Type

Screw

Removable Terminals

Yes

Vibration

9-150 Hz at 1g occasional/0.5g continuous

IP Rating

IP20

PL Rating

e

Safety Category Rating

4

SIL Rating

3

SISTEMA

PFHd = 4 x 10-10

THC Rating

IIIC

Safety Input – Single Channel

5-50 mA @ 24 V dc

Input Resistance

150 Ω max. per lead

E-Stops/Rope Pulls

Yes

Safety Mat

Yes

Motor Speed

No

Two-Hand Controls

Yes

Muting

Yes

Gate Switch (NC/NC) Input

Yes

Gate Switch (NC/NO) Input

Yes

Gate Switch (OSSD) Input

Yes

Light Curtains/Scanner with EDM Input

Yes

Light Curtains/Scanner without EDM Input

Yes

Recovery Time

250 (typical), 400 (max)