Power | DC |
Device Type | Safety Controller |
In-Series Diagnostics | No |
Safety Module Type | Base Controller |
LCD Display | Yes |
Expandable | Yes |
Dimension (H x W x D in mm) | 110 x 45 x 129 |
Relative Humidity | 90% @ 50° C |
Max Operating Temperature ( °C) | 55 |
Input Operation | Simultaneous or Concurrent |
Number of Safe Inputs | 26 |
Input Configuration | Configurable |
Number of Convertible Inputs | 8 |
Safety Input – Dual Channel (Dry Contact) | 5-50 mA @ 24 V dc |
Safety Input – Dual Channel (Solid-State) | 50 mA @ 15 – 30 V dc |
Safety Input – Reset | 5-50 mA @ 24 V dc |
Independently Controlled Safe Outputs | 4 |
Output Configuration | 2 OSSD Pairs |
Non Safe Output Configuration | Up to 11 PNP |
Non Safe Output Rating | 80 mA @ 24 V dc (individual) max for IOx; overcurrent protected, 500 mA @ 24 V dc for Sox |
Safe Output Rating | OSSD 0.50 A max. @ 24 V dc |
Splittable Safe Output | Yes |
Power Consumption | 0.16 A (controller only); 3.6 A (bus load) |
Response Time (ms) | See Software Configuration Summary |
Supply Voltage | 24 V dc +/- 20% |
Terminal Type | Screw |
Removable Terminals | Yes |
Vibration | 9-150 Hz at 1g occasional/0.5g continuous |
IP Rating | IP20 |
PL Rating | e |
Safety Category Rating | 4 |
SIL Rating | 3 |
SISTEMA | PFHd = 1.05 x 10-9 |
THC Rating | IIIC |
Safety Input – Single Channel | 5-50 mA @ 24 V dc |
Input Resistance | 150 Ω max. per lead |
E-Stops/Rope Pulls | Yes |
Safety Mat | Yes |
Motor Speed | No |
Two-Hand Controls | Yes |
Muting | Yes |
Gate Switch (NC/NC) Input | Yes |
Gate Switch (NC/NO) Input | Yes |
Gate Switch (OSSD) Input | Yes |
Light Curtains/Scanner with EDM Input | Yes |
Light Curtains/Scanner without EDM Input | Yes |
EtherNet/IP | Yes |
Modbus/TCP | Yes |
PCCC | Yes |
PROFINET | Yes |
Recovery Time | 250 (typical), 400 (max) |